Endoskopie, 2010; 19(3-4): 117-120

Capsule endoscopy in patient with Inflammatory Bowel Diseases

MUDr.Tomáš Douda, Ph.D.
II. interní klinika LF UK a FN Hradec Králové

The best indication for performing wireless capsule endoscopy in patient with Inflammatory Bowel Diseases is suspected Crohn´s disease.

Capsule can detect early small bowel involvement missed by other imaging techniques. Sensitivity capsule endoscopy is higher than

for push-enteroscopy, CT/MR enteroclysis. Capsule endoscopy is useful in distinguishing between ulcerative and Crohn’s colitis and can

better detect extent of disease. Capsule retention can occur. Stenosis is contraindication for capsule endoscopy. Scores for assessing the

activity or severity of Crohn’s disease by capsule endoscopy is not widely accepted and validated prospectively. Further research is

needed in the evaluation of diagnostic yield of capsule endoscopy in IBD patient.

Keywords: inflammatory bowel disease, Crohn´s disease, capsule endoscopy, activity index

Published: November 24, 2010  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Douda T. Capsule endoscopy in patient with Inflammatory Bowel Diseases. Endoskopie. 2010;19(3-4):117-120.
Download citation

References

  1. Rejchrt S, Drastich P, Kopáčova M, Tachecí I, Špičák J, Bureš J. Standard endoskopického vyšetření tenkého střeva diagnostickou kapslí. Čes Slov Gastroent a Hepatol 2004; 58: 24-27.
  2. Tachecí I, Drastich P, Suchánek Š, et al. Kapslová endoskopie - standard endoskopického vyšetření tenkého střeva. Čes a Slov Gastroent a Hepatol 2007; 61(5): 269-275.
  3. Tachecí I, et al. Kapslová endoskopie. Hradec Králové: Nucleus HK, 2008.
  4. Novotný A, Lukáš M. Crohnova choroba tenkého střeva. In: Tachecí I et al. Kapslová endoskopie. Hradec Králové: Nucleus HK, 2008.
  5. Bourreille A, et al. Role of small-bowel endoscopy in IBD: international OMED-ECCO consensus. Endoscopy 2009; 41: 618-637. Go to original source... Go to PubMed...
  6. Liangpunsakul S, Chadalawada V, Rex DK, Maglinte D, Lappas J. Wireless capsule endoscopy detects small bowel ulcers in patients with normal results from state of the art enteroclysis Am J Gastroenterol. 2003; 98(6): 1295-1298. Go to original source... Go to PubMed...
  7. Chong AK, Taylor A, Miller A, Hennessy O, Connell W, Desmond P. Capsule endoscopy vs. push enteroscopy and enteroclysis in suspected small-bowel Crohn's disease. Gastrointest Endosc. 2005 Feb; 61(2): 262-263. Go to original source... Go to PubMed...
  8. Marmo R, et al. Capsule endoscopy versus enteroclysis in the detection of small-bowel involvement in Crohn's disease: a prospective trial. Clin. Gastroenterol. Hepatol 2005; 3(8): 772-776. Go to original source... Go to PubMed...
  9. Voderholzer WA, et al. Small bowel involvement in Crohn's disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut 2005; 54(3): 323-326. Go to original source... Go to PubMed...
  10. Golder SK, Schreyer AG, Endlicher E, et al. Comparison of capsule endoscopy and magnetic resonance (MR) enteroclysis in suspected small bowel disease. Int. J. Colorectal Dis 2006; 21(2): 97-104. Epub 2005 Apr 22. Go to original source... Go to PubMed...
  11. Maunoury V, et al. Value of wireless capsule endoscopy in patients with indeterminate colitis (inflammatory bowel disease type unclassified). Inflamm. Bowel Dis. 2007; 13(2): 152-155. Go to original source... Go to PubMed...
  12. Mehdizadeh S, et al. Diagnostic yield of capsule endoscopy in ulcerative colitis and inflammatory bowel disease of unclassified type (IBDU). Endoscopy 2008; 40(1): 30-35. Epub 2007 Dec 5. Go to original source... Go to PubMed...
  13. Bourreille A, Jarry M, D'Halluin PN, et al. Wireless capsule endoscopy versus ileocolonoscopy for the diagnosis of postoperative recurrence of Crohn's disease: a prospective study. Gut 2006; N55, 978-983. Go to original source... Go to PubMed...
  14. Rutgeerts P, Geboes K, Vantrappen G, Beyls J, Kerremans R, Hiele M. Predictability of the postoperative course of Crohn's disease. Gastroenterology 1990; 99: 956-963. Go to original source... Go to PubMed...
  15. Gralnek IM, Defranchis R, Seidman E, Leighton JA, Legnani P, Lewis BS. Development of a capsule endoscopy scoring index for small bowel mucosal inflammatory change Aliment Pharmacol Therap 2008: 27: 146-154. Go to original source... Go to PubMed...
  16. Gal E, Geller A, Fraser G, Levi Z, Nivet. Assessment and Validation of the New Capsule Endoscopy Crohn's Disease Activity Index (CECDAI). Dig Dis Sci 2008; 53: 1933-1937. Go to original source... Go to PubMed...
  17. Cheon JH, Kim YS, Lee IS, et al. Can we predict spontaneous capsule passage after retention? A nationwide study to evaluate the incidence and clinical outcomes of capsule retention. Endoscopy 2007; 39: 1046-1052. Go to original source... Go to PubMed...
  18. Sachdev MS, Leighton JA, Fleischer DE, et al. A prospective study of the utility of abdominal radiographs after capsule endoscopy for the diagnosis of capsule retention. Gastrointest Endosc 2007; 66: 894-900. Go to original source... Go to PubMed...
  19. Li F, Gurudu SR, De Petris G, et al. Retention of the capsule endoscope: a single-center experience of 1,000 capsule endoscopy procedures. Gastrointest Endosc 2008; 68: 174-180. Go to original source... Go to PubMed...
  20. Delvaux M, Ben Soussan E, Laurent V, Lerebours E, Gay G. Clinical evaluation of the use of the M2A patency capsule system before a capsule endoscopy procedure, in patients with known or suspected intestinal stenosis. Endoscopy. 2005; 37(9): 801-807. Go to original source... Go to PubMed...
  21. Adler S, Infantolino A, Costamagna G, Leighton L, Herrerias J. Agile Patency System Eliminates Risk of Capsule Retention in Patients with Known Intestinal Strictures Who Undergo Capsule Endoscopy (CE). Gastrointest Endosc 2007; 65: AB318-AB318. Go to original source...
  22. Rejchrt S, Kopacova M, Tacheci I, Bures J. Interventional Double Balloon Endoscopy for Crohn's, Gastrointestinal Bleeding, and Foreign Body Extraction Tech Gastrointest Endosc 2008; 10: 101-106. Go to original source...
  23. Rejchrt S, Kopáčová M, Tachecí I, Bureš J. Retrieval of retained wireless capsule endoscope from the ileum by means of push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) in a patient with Crohn's disease. Folia Gastroenterol Hepatol 2006; 4(1): 33-37.
  24. Triester SL, Leighton JA, Leontiadis GI, et al. A metaanalysis of the yield of capsule endoscopy compared to other diagnostic modalitiesin patients with non-stricturing small bowel Crohn's disease. Am J Gastroenterol 2006; 101: 954-964. Go to original source... Go to PubMed...
  25. Trang CF, Le Rhun M, Maillard M, et al. A. Jejunal lesions seen by wireless capsule endoscopy in Crohn's disease: prevalence and clinical significance. Gastroenterology 2009; 136(Suppl): abstrakt. Go to original source...
  26. Leighton JA, Gralnek IM, Richner RE, Lacey MJ, Papatheofanis FJ. Capsule endoscopy in suspected small bowel Crohn's disease: economic impact of disease diagnosis and treatment. World J Gastroenterol. 2009; 15(45): 5685-5692. Go to original source... Go to PubMed...




Endoscopy

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.