Endoskopie 2010; 19(2): 79-84

Measurement of objects observed during endoscopy using the FOTOM 2008 system

doc.Ing.Lačezar Ličev, CSc.1, MUDr.Ondřej Urban, Ph.D.2,3,4
1 Katedra informatiky FEI, VŠB TU Ostrava
2 Centrum péče o zažívací trakt, Vítkovická nemocnice a. s., Ostrava
3 Interní klinika, Fakultní nemocnice Ostrava
4 Fakulta zdravotnických studií, OU v Ostravě

Endoscopic examination methods are widely used in diagnosis and treatment in many branches of medicine. Currently, the size of objects

observed endoscopically is most commonly determined by estimation or by comparing to an object of a known size introduced to the

observed area for this purpose. The authors present their initial experience with the development of a method allowing direct measurement

of the objects observed.

Keywords: endoscopy, calibration, transformation, measurement of objects

Published: June 1, 2010  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Ličev L, Urban O. Measurement of objects observed during endoscopy using the FOTOM 2008 system. Endoskopie. 2010;19(2):79-84.
Download citation

References

  1. Ličev L. Podrobnější analýza snímků. 12. konference SDMG, Ostrava, VŠB HGF, 2005.
  2. Ličev L, Farana R, Pajurek I. The FOTOM 2005 and More Detailed Image Analysis. In Proceedings of 7th International Carpathian Control Conference. Ostrava: VŠB-TU Ostrava, 2006: 349-352.
  3. Ličev L, Farana R, Pajurek I. Parameters and Shape of Metered Objects of Interest in Ultrasound Images Monitoring. In Proceedings of 8th International Carpathian Control Conference. Štrbské Pleso: TU Košice, May 24-27, 2007: 418-421.
  4. Ličev L. Systém FOTOM 2008 a vizualizace procesu měření. Ed. Ing. Kateřina Pešková. Ostrava: TANGER, spol. s. o., 2009; 1: 35-35. VŠB TU Ostrava, HGF, Institut geoinformatiky.
  5. Ličev L, Krumnikl M. The FOTOM System and metering process visualization. Ed. Koči P, Smutný P, Smutný L. FS VŠB TUO: FS VŠB TUO, XXXIV(1): 27 s. katedra ATŘ FS VŠB TUO.
  6. Ličev L, Krumnikl M. Transformation and image calibration for endoscopic image analysis in FOTOM 2008 system. Bulharsko: 9th International Multidisciplinary Scientific Geo Conference SGEM 2009; 9(1): Modern Management of Mine Producing, Geology and Enviromental Protection: 887-896.
  7. Schreiber J, Ličev L, Sojka E. Recognition and diagnostics of special objects in ultrasound images. 8th ICCC 2007. Štrbské pleso, Slovak Republic: 643-646.
  8. Schreiber J, Sojka E, Ličev L, et al. A new method for the detection of brain stem in transcranial ultrasound images. In: Biosignals. Funchal, Madeira, Portugal, 2008: 478-483.
  9. Sojka E. Digitální zpracování a analýza obrazů. 1st ed. Ostrava: VŠB-TUO, 2000.




Endoscopy

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.